[Back]NDIR Gas Analyzer
Product Overview

S-ANALYZER 200 series is a multi-gas analyzer for 19"rack-mounting. Up to 5 components can be measured and the measuring principles may be ordered in various combinations. S-ANALYZER 200 is equipped with a touchscreen. In combination with a well-arranged menu structure, intuitive and user-friendly operations is assured. All necessary status-, threshold-, and alarm messages for effective monitoring are provided as analogue and digital signals,included graphic display of measurement curves.

Specification:

Product TypeS-ANALYZER 200 
Channel           • Max. 5 measured Gases
 • Configuration information includes
-   measuring gas type
-   measurement range
-   measuring Error
Response timeGeneral:<25s   (t90 @60 L/h Constant Flow)
Warm up Time3min~30min  (accord different detector configuration)
Digital Res.  (@zeroGeneral:
 - 0.01Vol.% in case of percent range (e.g. 0.001Vol.% for BMBT O2 channel)
- 0.1 µmol/mol in case of µmol/mol range
Value IndicationDigital indication in Max. 6 digits
Operation HandlingTouch panel, 5.6” TFT
Analog Output4mA~20mA  (normal operation)
 2mA  (in warm-up or status alarm)
Permissible load resistance250Ω~350Ω
Alarm contact output• Instrument status alarm
 • upper/lower alarm
Note:
1. Relay contact close when the instantaneous measure value of each channel becomes larger than the upper alarm limit value or smaller than the lower alarm limit value.
2. All relay contacts are isolated mutually and from the internal circuit
Relay Property1A contact  (250V AC/2A, resistive load)
CommunicationRS232  (DB-9 Female)
Operating Voltage198~242V AC, 50/60 Hz
Power inletEN60320 C1
FuseFuse Current: 3A ,Blow Characteristic: Fast Acting
 Fuse Size Metric: 5mm x 20mm
Case Protection LevelIP42  (EN60529)
WeightApprox. 15Kg  (typical)
Gas Inlet Flow0.4~0.8 L/min  (Flow fluctuations ≤0.02 L/min)
Inlet Gas Temp.5~35 ℃
Inlet Gas Pressure116kPa  (max)
Moisture in Gas• not condensing
 • inlet gas dew point:5℃±0.1℃
 (This item is required when measure channel include  NDIR SO2 and/or NO)
Dust in gas flow100µg/m³, ≤1µm
Zero calibration gas99.999Vol.% N2 (typical)
Span calibration gas75Vol.% FS~110Vol.% FS
 Note:
For O2 channel, could use dry and clean air to make span calibration if the measuring range is  (0…25Vol.%.)
3th point calibration gas35Vol.% FS~75Vol.% FS

 

Product Description:

S-ANALYZER 200 series is a multi-gas analyzer for 19"rack-mounting. Up to 5 components can be measured and the measuring principles may be ordered in various combinations. S-ANALYZER 200 is equipped with a touchscreen. In combination with a well-arranged menu structure, intuitive and user-friendly operations is assured. All necessary status-, threshold-, and alarm messages for effective monitoring are provided as analogue and digital signals,also included graphic display of measurement curves.

-   Environment pollution control

-   Service and testing

-   Waste gas analysis

-   Process gas analysis

-   Air quality control

-   TOC value measurement

-   Blast furnace gas detection

-   Garbage landfill

-   Tunnel gas detection

 

Product Features:

-   SA-200 with touch screen control, all function in one hand.

-   Three screen switch function

-   Screen 1: Value status, include menu and error information

-   Screen 2: real-time gas concentration and value change

-   Screen 3: real-time gas concentration curve

-   Calibration menu, alarm set with password control

-   Function of zero, span and third point calibration to get better linearity.

-   Free to choose English and Chinese menu

-   one button with “back to factory setting” to provide wrong operation.

Product Overview

S-ANALYZER 200 series is a multi-gas analyzer for 19"rack-mounting. Up to 5 components can be measured and the measuring principles may be ordered in various combinations. S-ANALYZER 200 is equipped with a touchscreen. In combination with a well-arranged menu structure, intuitive and user-friendly operations is assured. All necessary status-, threshold-, and alarm messages for effective monitoring are provided as analogue and digital signals,included graphic display of measurement curves.

Specification:

Product TypeS-ANALYZER 200 
Channel           • Max. 5 measured Gases
 • Configuration information includes
-   measuring gas type
-   measurement range
-   measuring Error
Response timeGeneral:<25s   (t90 @60 L/h Constant Flow)
Warm up Time3min~30min  (accord different detector configuration)
Digital Res.  (@zeroGeneral:
 - 0.01Vol.% in case of percent range (e.g. 0.001Vol.% for BMBT O2 channel)
- 0.1 µmol/mol in case of µmol/mol range
Value IndicationDigital indication in Max. 6 digits
Operation HandlingTouch panel, 5.6” TFT
Analog Output4mA~20mA  (normal operation)
 2mA  (in warm-up or status alarm)
Permissible load resistance250Ω~350Ω
Alarm contact output• Instrument status alarm
 • upper/lower alarm
Note:
1. Relay contact close when the instantaneous measure value of each channel becomes larger than the upper alarm limit value or smaller than the lower alarm limit value.
2. All relay contacts are isolated mutually and from the internal circuit
Relay Property1A contact  (250V AC/2A, resistive load)
CommunicationRS232  (DB-9 Female)
Operating Voltage198~242V AC, 50/60 Hz
Power inletEN60320 C1
FuseFuse Current: 3A ,Blow Characteristic: Fast Acting
 Fuse Size Metric: 5mm x 20mm
Case Protection LevelIP42  (EN60529)
WeightApprox. 15Kg  (typical)
Gas Inlet Flow0.4~0.8 L/min  (Flow fluctuations ≤0.02 L/min)
Inlet Gas Temp.5~35 ℃
Inlet Gas Pressure116kPa  (max)
Moisture in Gas• not condensing
 • inlet gas dew point:5℃±0.1℃
 (This item is required when measure channel include  NDIR SO2 and/or NO)
Dust in gas flow100µg/m³, ≤1µm
Zero calibration gas99.999Vol.% N2 (typical)
Span calibration gas75Vol.% FS~110Vol.% FS
 Note:
For O2 channel, could use dry and clean air to make span calibration if the measuring range is  (0…25Vol.%.)
3th point calibration gas35Vol.% FS~75Vol.% FS

 

Product Description:

S-ANALYZER 200 series is a multi-gas analyzer for 19"rack-mounting. Up to 5 components can be measured and the measuring principles may be ordered in various combinations. S-ANALYZER 200 is equipped with a touchscreen. In combination with a well-arranged menu structure, intuitive and user-friendly operations is assured. All necessary status-, threshold-, and alarm messages for effective monitoring are provided as analogue and digital signals,also included graphic display of measurement curves.

-   Environment pollution control

-   Service and testing

-   Waste gas analysis

-   Process gas analysis

-   Air quality control

-   TOC value measurement

-   Blast furnace gas detection

-   Garbage landfill

-   Tunnel gas detection

 

Product Features:

-   SA-200 with touch screen control, all function in one hand.

-   Three screen switch function

-   Screen 1: Value status, include menu and error information

-   Screen 2: real-time gas concentration and value change

-   Screen 3: real-time gas concentration curve

-   Calibration menu, alarm set with password control

-   Function of zero, span and third point calibration to get better linearity.

-   Free to choose English and Chinese menu

-   one button with “back to factory setting” to provide wrong operation.

SIGAS Measurement Engineering Corp. ICP-19046713
RnD & Production Center: Building 15, No. 59 Jiangnan Rd, CEDZ, Changshu, Jiangsu Province, China | Tel.: +86-(0)512-52265350 Fax: +86-(0)512-52265360
SIGAS Nanjing: Office 705, Building 3, No. 9 Weidi Rd. Qixia District, Nanjing, Jiangsu Province, China | Tel.: +86-(0)25-85576826 Fax: +86-(0)25-85576826
SIGAS Beijing: Office 1210, No. 42, Dong Zhi Men Wai Str. Yu Fei Building, Chaoyang District, Beijing, China | Tel: +86-(0)10-64638812 Fax: +86-(0)10-64638812
SIGAS Shanghai: Office 613 Area A, 6th floor, No. 1866, Hutai Road, Baoshan District, Shanghai, China | Tel.: +86-(0)21-31499266