The S-ULTRA.sens module uses modern optical components to achieve optimized analyzer results. We use a special LED/EDL-Technology in order to get stable radiation emission. The result is a high resolution gas analysis system which can detect gas concentration changes of less than 1ppm .
Standard gas measurement type (other gas and range please contact us):
S-UltraSense | NO | 0-300ppm |
S-UltraSense | O3 | 0-100ppm |
S-UltraSense | O3+CnHm | O3 0-25ppm / CnHm 0-500ppm |
S-UltraSense | H2S | H2S 0-100ppm / 0-500ppm / 0-1500ppm / 0-5000ppm |
S-UltraSense | H2S (Background gas CH4) | H2S 0-100ppm |
S-UltraSense | NO/NO2/SO2 | NO 0-300ppm / NO2 0-200ppm / SO2 0-200ppm |
S-UltraSense | SO2/NO2 | SO2 0-1000ppm / NO2 0-1000ppm |
S-UltraSense | NO2/N2O | NO2 0-2000ppm / N2O 0-2000ppm |
S-UltraSense | N2O | 0-1000ppm |
S-UltraSense | SO2 | 0-100ppm / 0-500ppm |
S-UltraSense | SO2 dual range | 0-1000ppm (LDL 1ppm), 0-30000ppm(LDL 20ppm) |
Specification:
Measurement Technology | NDUV |
Heating Tem. | 42.10 |
T90 Response time | <3s@1L/min |
Digital resolution(@zero) | 1ppm...0.1 Vol.% |
Detection Limit (3sigma) | ±0.5%FS |
Repeatability | ±1%FS |
Linearity Error | ±1%FS |
Stability (zero) | ±1%FS |
Stability (span) | ±1%FS |
Temperature Drift. (zero) | ±1%FS per 10K |
Temperature Drift. (span) | ±1%FS per 10K |
Pressure Drift. | ±0.015% /mbar |
Operating Temp | 10...40℃ |
Storage Temp | -10...60℃ |
Ambient Humidity | 0 % up to 95 % rel. Humidity (not condensing ) |
Ambient Air Pressure | 800...1200 mbar |
Warm up Time | <60min (related to environment Tem.) <30min @20℃ environment Tem. |
Start time | <2 min (reach the heating Tem.) |
Flow gas Tem. | -2℃...40℃ |
Flow gas Humidity | Max. 10℃ (not condensing) |
Gas flow | 0.2...1L/min (stable flow) |
Output Signal | RS232 9P-Sub-D 和 2x5pin 2.45mm connector |
Operating Voltage | 24VDC±0.3V 3A |
Power consumption | 4W (Heating max. 55W) |
Products Description:
The gas analysis based on the NDUV techniques is a well-known method to determine the concentration in complex gas mixtures. The S-ULTRA.sens module uses modern optical components to achieve optimized analyzer results.
We use a special LED/EDL-Technology in order to get stable radiation emission. The result is a high resolution gas analysis system which can detect gas concentration changes of less than 1ppm .
The entire structure can be disassembled to make the maintenance/service easier. The different devices are sealed with O-Ring joining. The stainless steel sample cell is coated with a protection layer. The length is 100mm. For the combined detection of NO, NO2 and SO2 three different light sources are integrated.
For example, we use AlGaN-LED for the UV light source which can cover 360-230nm wave length. For enhance the life time of the light source, we use special control board, which can let the light source achieve more than 3 years life time, which solve the well-know problem of shortcoming of UV light source.
S-ULTRA.sens is suitable for all kind of complex industry environment, special has good performance in low range CEMS measurement, which can good measure NO and NO2 without transition device.
The S-ULTRA.sens module uses modern optical components to achieve optimized analyzer results. We use a special LED/EDL-Technology in order to get stable radiation emission. The result is a high resolution gas analysis system which can detect gas concentration changes of less than 1ppm .
Standard gas measurement type (other gas and range please contact us):
S-UltraSense | NO | 0-300ppm |
S-UltraSense | O3 | 0-100ppm |
S-UltraSense | O3+CnHm | O3 0-25ppm / CnHm 0-500ppm |
S-UltraSense | H2S | H2S 0-100ppm / 0-500ppm / 0-1500ppm / 0-5000ppm |
S-UltraSense | H2S (Background gas CH4) | H2S 0-100ppm |
S-UltraSense | NO/NO2/SO2 | NO 0-300ppm / NO2 0-200ppm / SO2 0-200ppm |
S-UltraSense | SO2/NO2 | SO2 0-1000ppm / NO2 0-1000ppm |
S-UltraSense | NO2/N2O | NO2 0-2000ppm / N2O 0-2000ppm |
S-UltraSense | N2O | 0-1000ppm |
S-UltraSense | SO2 | 0-100ppm / 0-500ppm |
S-UltraSense | SO2 dual range | 0-1000ppm (LDL 1ppm), 0-30000ppm(LDL 20ppm) |
Specification:
Measurement Technology | NDUV |
Heating Tem. | 42.10 |
T90 Response time | <3s@1L/min |
Digital resolution(@zero) | 1ppm...0.1 Vol.% |
Detection Limit (3sigma) | ±0.5%FS |
Repeatability | ±1%FS |
Linearity Error | ±1%FS |
Stability (zero) | ±1%FS |
Stability (span) | ±1%FS |
Temperature Drift. (zero) | ±1%FS per 10K |
Temperature Drift. (span) | ±1%FS per 10K |
Pressure Drift. | ±0.015% /mbar |
Operating Temp | 10...40℃ |
Storage Temp | -10...60℃ |
Ambient Humidity | 0 % up to 95 % rel. Humidity (not condensing ) |
Ambient Air Pressure | 800...1200 mbar |
Warm up Time | <60min (related to environment Tem.) <30min @20℃ environment Tem. |
Start time | <2 min (reach the heating Tem.) |
Flow gas Tem. | -2℃...40℃ |
Flow gas Humidity | Max. 10℃ (not condensing) |
Gas flow | 0.2...1L/min (stable flow) |
Output Signal | RS232 9P-Sub-D 和 2x5pin 2.45mm connector |
Operating Voltage | 24VDC±0.3V 3A |
Power consumption | 4W (Heating max. 55W) |
Products Description:
The gas analysis based on the NDUV techniques is a well-known method to determine the concentration in complex gas mixtures. The S-ULTRA.sens module uses modern optical components to achieve optimized analyzer results.
We use a special LED/EDL-Technology in order to get stable radiation emission. The result is a high resolution gas analysis system which can detect gas concentration changes of less than 1ppm .
The entire structure can be disassembled to make the maintenance/service easier. The different devices are sealed with O-Ring joining. The stainless steel sample cell is coated with a protection layer. The length is 100mm. For the combined detection of NO, NO2 and SO2 three different light sources are integrated.
For example, we use AlGaN-LED for the UV light source which can cover 360-230nm wave length. For enhance the life time of the light source, we use special control board, which can let the light source achieve more than 3 years life time, which solve the well-know problem of shortcoming of UV light source.
S-ULTRA.sens is suitable for all kind of complex industry environment, special has good performance in low range CEMS measurement, which can good measure NO and NO2 without transition device.