[Back]NDIR multi-Gas Module Silarex
Product Overview

The Silarex is one high-end type of multi-gas measurement sensor which based on the infrared absorption technology and comply with the highest standards in accuracy, reliability and efficiency. Due the consequent use of this optical principle the systems work without abrasion or chemical reactions and are nearly maintenance free.

Product Type:

S-0006558 S-Module Silarex NO 1000ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0005856 S-Module Silarex CO 1000ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0006547 S-Module Silarex CO2 20% CO 500ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0005200 S-Module Silarex CO2 20% CO 1000ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0005470 S-Module Silarex CO2 20% CO 3000ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0005626 S-Module Silarex CO2 20% CO 5000ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0006978 S-Module Silarex CO2 20% CO 1000ppm 340mm (cased) ModBus RS232 6/4mm tube
S-0005355 S-Module Silarex CO2 20% CO 10000ppm 340mm (cased) RS232 5/3mm tube
S-0005304 S-Module Silarex CO2 20% SO2 1000ppm NO 2000ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0005317 S-Module Silarex CO2 25% SO2 3000ppm NO 5000ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0005332 S-Module Silarex multi (EVO) CO 2000ppm SO2 2000ppm NO 2000ppm (cased) RS232 5/3mm tube
S-0005346 S-Module Silarex multi (EVO) CO 2000ppm SO2 1000ppm NO 2000ppm (cased) RS232 5/3mm tube
S-0005347 S-Module Silarex multi (EVO) CO 2000ppm CO2 20% SO2 1000ppm NO 2000ppm (cased) RS232 5/3mm tube
S-0005761 S-Module Silarex multi (EVO) CO 5% CO2 20% SO2 1000ppm NO 2000ppm (cased) ModBus RS232 5/3mm tube
S-0005938 S-Module Silarex CO2 20% SO2 1000ppm NO 2000ppm 340mm (cased) with external RS232 and 4..20mA 5/3mm tube
S-0006934 S-Module Silarex CO2 20% SO2 300ppm NO 500ppm 340mm (cased) with external RS232 and 4..20mA 5/3mm tube


Specification:

Detection PrincipleNDIR (Dual Beam)
Measuring RangeSee List
Gas SupplyFlow
DimensionsSee Mechanical Data
Hose connection3mm internal, 5mm outside
Heated Tem.Internal 42°C
Response time (T90)< 8sec @0.7 l/min (default)
Repeatability≤ ±1 % FS
Linearity Error≤ ±1 % FS ( or ≤ ±1.5 % FS depend on version)
Stability< ±2% [FS] @1000h
Operating Temp0 °C up to 40 °C
Storage Temp-20 °C up to 60 °C
Ambient Humidity0 % up to 95 % rel. Humidity (Non-condensing)
Ambient Air Pressure800 ... 1150 mbar
Warm up Time< 2 minutes (Cold start)          < 30 minutes according to heat isolation and environment Tem.
Flow0,2up to 1,0 L / min (const flow)
Gas Inlet Tem.2 ... +42°C
Gas Inlet Humidity5°C max ±1K (need cooler)
Diginal Output SignalModbus ASCII RTU TTL
2400-115.200 auto Baud/ auto Frame
Operation power24 VDC  ±0.3V
Driven Current240mA / max 1.5A during Heating
Power Consumption< 800 mW / max 36W during Heating


Specification S-0005200 S-Module Silarex CO2 20% CO 1000ppm 340mm (cased)
Digital Resolution  (@zero)CO2 20Vol.%0.01Vol.%
CO 1000ppm0.1ppm
Detection Limit (3sigma)CO20.1%[FS]
CO0.5%[FS]
Cross SensitivityCO2 to CO<10ppm@ 20Vol.% CO2
SO2 to CO<10ppm@100ppmSO2
NO to CO<10ppm@100ppmNO
NO2 to CO<10ppm@100ppmNO2
CH4 to CO<30ppm@1Vol.% CH4
CH4 to CO<150ppm@ 5Vol.% CH4
SO2 to CO<25ppm@500ppm SO2
SO2 to CO<45ppm@1000ppm SO2
NO to CO<40ppm@1000ppm NO


Specification S-0005200 S-Module Silarex CO2 20% CO 1000ppm 340mm (cased)
Digital Resolution  (@zero) CO2 20Vol.%: 0.01Vol.%
NO  2000ppm 1ppm
SO2 1000ppm 1ppm
Detection Limit (3sigma) CO2 0.1%[FS]
NO 1%[FS]
SO2 1%[FS]
Cross Sensitivity CO2 to SO2 < 10ppm @ 20Vol.% CO
CO2 to NO < 20ppm @ 20Vol.% CO2
SO2 to NO < 20ppm @ 1000ppm SO2
NO  to SO2 <2ppm @ 1500ppm NO
DP  to NO < 30ppm @ 4.5 ±1°C
DP to SO2 < 20ppm @ 4.5 ±1°C



Product Description:

 

The Silarex  is one high-end type of multi-gas measurement sensor which based on the infrared absorption technology and comply with the highest standards in accuracy, reliability and efficiency.

Due the consequent use of this optical principle the systems work without abrasion or chemical reactions and are nearly maintenance free.

 

As basis the IR principle uses the individual absorption spectrum of the gas to be detected and specifies the concentration by the precise quantitative analysis.

Because all measured gases absorb IR radiation in a different spectrum a so called “fingerprint” is given which ensures a selective characterization with less cross sensitivities. 

An integrated evaluation electronic delivers finally an easy to use concentration signal and compensates all temperature- and drift effects.

 

The Silarex housing is made with gold plating housing which can effectively reduce the noise of light source. And the gas Inlet and Outlet are fitted with gas line connectors to allow perfusion of the Silarex.  Tubing with an internal diameter of 3 mm and external diameter of 5 mm is needed to connect up to the measurement cell. Ensure that tubing is securely attached to the inlet and outlet connectors.

 

Meanwhile we have equipped Silarex with heated aluminium Housing to make the stable temperature of sensor, to reduce the fluctuation of measurement date due to the unstable environment temperature. Also with pressure sensor to reduce the gas flow influence. Silarex is the right product for all kind of industry stable gas measurement application.

Product Overview

The Silarex is one high-end type of multi-gas measurement sensor which based on the infrared absorption technology and comply with the highest standards in accuracy, reliability and efficiency. Due the consequent use of this optical principle the systems work without abrasion or chemical reactions and are nearly maintenance free.

Product Type:

S-0006558 S-Module Silarex NO 1000ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0005856 S-Module Silarex CO 1000ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0006547 S-Module Silarex CO2 20% CO 500ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0005200 S-Module Silarex CO2 20% CO 1000ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0005470 S-Module Silarex CO2 20% CO 3000ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0005626 S-Module Silarex CO2 20% CO 5000ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0006978 S-Module Silarex CO2 20% CO 1000ppm 340mm (cased) ModBus RS232 6/4mm tube
S-0005355 S-Module Silarex CO2 20% CO 10000ppm 340mm (cased) RS232 5/3mm tube
S-0005304 S-Module Silarex CO2 20% SO2 1000ppm NO 2000ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0005317 S-Module Silarex CO2 25% SO2 3000ppm NO 5000ppm 340mm (cased) ModBus RS232 5/3mm tube
S-0005332 S-Module Silarex multi (EVO) CO 2000ppm SO2 2000ppm NO 2000ppm (cased) RS232 5/3mm tube
S-0005346 S-Module Silarex multi (EVO) CO 2000ppm SO2 1000ppm NO 2000ppm (cased) RS232 5/3mm tube
S-0005347 S-Module Silarex multi (EVO) CO 2000ppm CO2 20% SO2 1000ppm NO 2000ppm (cased) RS232 5/3mm tube
S-0005761 S-Module Silarex multi (EVO) CO 5% CO2 20% SO2 1000ppm NO 2000ppm (cased) ModBus RS232 5/3mm tube
S-0005938 S-Module Silarex CO2 20% SO2 1000ppm NO 2000ppm 340mm (cased) with external RS232 and 4..20mA 5/3mm tube
S-0006934 S-Module Silarex CO2 20% SO2 300ppm NO 500ppm 340mm (cased) with external RS232 and 4..20mA 5/3mm tube


Specification:

Detection PrincipleNDIR (Dual Beam)
Measuring RangeSee List
Gas SupplyFlow
DimensionsSee Mechanical Data
Hose connection3mm internal, 5mm outside
Heated Tem.Internal 42°C
Response time (T90)< 8sec @0.7 l/min (default)
Repeatability≤ ±1 % FS
Linearity Error≤ ±1 % FS ( or ≤ ±1.5 % FS depend on version)
Stability< ±2% [FS] @1000h
Operating Temp0 °C up to 40 °C
Storage Temp-20 °C up to 60 °C
Ambient Humidity0 % up to 95 % rel. Humidity (Non-condensing)
Ambient Air Pressure800 ... 1150 mbar
Warm up Time< 2 minutes (Cold start)          < 30 minutes according to heat isolation and environment Tem.
Flow0,2up to 1,0 L / min (const flow)
Gas Inlet Tem.2 ... +42°C
Gas Inlet Humidity5°C max ±1K (need cooler)
Diginal Output SignalModbus ASCII RTU TTL
2400-115.200 auto Baud/ auto Frame
Operation power24 VDC  ±0.3V
Driven Current240mA / max 1.5A during Heating
Power Consumption< 800 mW / max 36W during Heating


Specification S-0005200 S-Module Silarex CO2 20% CO 1000ppm 340mm (cased)
Digital Resolution  (@zero)CO2 20Vol.%0.01Vol.%
CO 1000ppm0.1ppm
Detection Limit (3sigma)CO20.1%[FS]
CO0.5%[FS]
Cross SensitivityCO2 to CO<10ppm@ 20Vol.% CO2
SO2 to CO<10ppm@100ppmSO2
NO to CO<10ppm@100ppmNO
NO2 to CO<10ppm@100ppmNO2
CH4 to CO<30ppm@1Vol.% CH4
CH4 to CO<150ppm@ 5Vol.% CH4
SO2 to CO<25ppm@500ppm SO2
SO2 to CO<45ppm@1000ppm SO2
NO to CO<40ppm@1000ppm NO


Specification S-0005200 S-Module Silarex CO2 20% CO 1000ppm 340mm (cased)
Digital Resolution  (@zero) CO2 20Vol.%: 0.01Vol.%
NO  2000ppm 1ppm
SO2 1000ppm 1ppm
Detection Limit (3sigma) CO2 0.1%[FS]
NO 1%[FS]
SO2 1%[FS]
Cross Sensitivity CO2 to SO2 < 10ppm @ 20Vol.% CO
CO2 to NO < 20ppm @ 20Vol.% CO2
SO2 to NO < 20ppm @ 1000ppm SO2
NO  to SO2 <2ppm @ 1500ppm NO
DP  to NO < 30ppm @ 4.5 ±1°C
DP to SO2 < 20ppm @ 4.5 ±1°C



Product Description:

 

The Silarex  is one high-end type of multi-gas measurement sensor which based on the infrared absorption technology and comply with the highest standards in accuracy, reliability and efficiency.

Due the consequent use of this optical principle the systems work without abrasion or chemical reactions and are nearly maintenance free.

 

As basis the IR principle uses the individual absorption spectrum of the gas to be detected and specifies the concentration by the precise quantitative analysis.

Because all measured gases absorb IR radiation in a different spectrum a so called “fingerprint” is given which ensures a selective characterization with less cross sensitivities. 

An integrated evaluation electronic delivers finally an easy to use concentration signal and compensates all temperature- and drift effects.

 

The Silarex housing is made with gold plating housing which can effectively reduce the noise of light source. And the gas Inlet and Outlet are fitted with gas line connectors to allow perfusion of the Silarex.  Tubing with an internal diameter of 3 mm and external diameter of 5 mm is needed to connect up to the measurement cell. Ensure that tubing is securely attached to the inlet and outlet connectors.

 

Meanwhile we have equipped Silarex with heated aluminium Housing to make the stable temperature of sensor, to reduce the fluctuation of measurement date due to the unstable environment temperature. Also with pressure sensor to reduce the gas flow influence. Silarex is the right product for all kind of industry stable gas measurement application.

SIGAS Measurement Engineering Corp. ICP-19046713
RnD & Production Center: Building 15, No. 59 Jiangnan Rd, CEDZ, Changshu, Jiangsu Province, China | Tel.: +86-(0)512-52265350 Fax: +86-(0)512-52265360
SIGAS Nanjing: Office 705, Building 3, No. 9 Weidi Rd. Qixia District, Nanjing, Jiangsu Province, China | Tel.: +86-(0)25-85576826 Fax: +86-(0)25-85576826
SIGAS Beijing: Office 1210, No. 42, Dong Zhi Men Wai Str. Yu Fei Building, Chaoyang District, Beijing, China | Tel: +86-(0)10-64638812 Fax: +86-(0)10-64638812
SIGAS Shanghai: Office 613 Area A, 6th floor, No. 1866, Hutai Road, Baoshan District, Shanghai, China | Tel.: +86-(0)21-31499266